|
|
|
|
Report Cover Table of Contents Sec. 1 Sec. 2 Sec. 3 Sec. 4 Sec. 5 Sec. 6 Sec. 7 Sec. 8 SECTION 8 REFERENCES Britt, S.L., B.L. Parker, and J.A. Cherry. 2005. Field Testing the Snap Sampler A Comparison with Low Flow and Polyethylene Diffusion Samplers. Battelle In Situ and On Site Bioremediation Symposium, Baltimore MD. June. California Regional Water Quality Control Board. 2003. Memo entitled Request for a Technical Report on Emergent Chemical Sources and Sampling. Central Valley Region. June 11. Church, P.E. 2000. Evaluation of a Diffusion Sampling Method for Determining Concentrations of Volatile Organic Compounds in Ground Water, Hanscom Air Force Base, Bedford, Massachusetts. U.S. Geological Survey Water-Resources Investigations Report 00-4242, 20 p. Ehlke, T.A., Imbrigiotta, T.E., and Dale, J.M. 2004. Laboratory comparison of polyethylene and dialysis membrane diffusion samplers. Ground Water Monitoring and Remediation, v. 24, no. 1, p. 53-59. Hare, P.W. 2000. Passive Diffusion Bag Samplers for Monitoring Chlorinated Solvents in Ground Water. Proceedings of the Second International Conference on Remediation of Chlorinated and Recalcitrant Compounds, Battelle, May 22-25, 2000, Monterey, California, v.2, no 1, p. 377-386. Imbrigiotta, T.E., Ehlke, T.A., Lacombe, P.J., and Dale, J.M. 2002. Comparison of dialysis membrane diffusion samplers and two purging methods in bedrock wells. In A.R. Gavaskar and A.S.C. Chen (Eds.), Remediation of Chlorinated and Recalcitrant Compounds. Proceedings of the Third International Conference on Remediation of Chlorinated and Recalcitrant Compounds, Monterey, CA. May 2002. Interstate Technology Regulatory Council. 2004. Technical and Regulatory Guidance for Using Polyethylene Diffusion Bag Samplers to Monitor Volatile Organic Compounds in Groundwater. February. Jackson, A. 2003. Peeper Samplers. Presentation to the Diffusion Sampling Workgroup at the ITRC Fall Membership Meeting. Monterey, CA. October 1. McClellan AFB. 2000. Final Passive Diffusion Membrane Samplers Technology Application Analysis Report. National Environmental Technology Test Sites (NETTS). August. Newell, C.J., Lee, R.S., Spexet, A.H. 2000. No-Purge Groundwater Sampling, An Approach for Long-Term Monitoring. Published by the American Petroleum Institute, No. 12, October. Parsons Engineering Science, Inc. (Parsons). 1999. Final Technical Report for the Evaluation of Groundwater Diffusion Samplers. December. Parsons. 2003a. Final Work Plan for the Air Force Real Property Agency Passive Diffusion Sampler Demonstration. April. Parsons. 2003b. Final Comprehensive Results Report for the Passive Diffusion Bag Sampler Demonstration. July. Parsons. 2004a. Final Work Plan for the Demonstration of Passive Groundwater Sampling Devices at Former McClellan AFB, California. May. Parsons. 2004b. Final Comprehensive Results Report for the Passive Diffusion Bag Sampler Demonstration. October. URS. 2003. Former McClellan Air Force Base Basewide Quality Assurance Project Plan. Revision 5. September. Vroblesky, D.A., Petkewich, M.D., and Campbell, T.R. 2002. Field tests of diffusion samplers for inorganic constituents in wells and at a ground-water-discharge zone. U.S. Geological Survey Water Resources Investigation Report 02-4031 , 24 p. Vroblesky, D.A., and Pravecek, Tasha. 2002. Evaluation of passive diffusion bag and dialysis samplers in selected wells at Hickam Air Force Base, Hawaii, July 2001. U.S. Geological Survey Water Resources Investigations Report 02-4159, 38 p. Vroblesky, D.A. 2001. User's Guide for Polyethylene-Based Passive Diffusion Bag Samplers to Obtain Volatile Organic Compound Concentrations in Wells. US Geological Survey Water-Resources Investigations Report 01-4060. Columbia, South Carolina. Vroblesky, D.A., Borchers, J.W., Campbell, T.R., and Kinsey, W. 2000. Investigation of Polyethylene Passive Diffusion Samplers for Sampling Volatile Organic Compounds in Ground Water at Davis Global Communication, Sacramento, California. August 1998 to February 1999: U.S. Geological Survey Open-File Report 00-307, 13 p. Vroblesky, D.A., and Hyde, W.T. 1997. Diffusion samplers as an Inexpensive Approach to Monitoring VOCs in Ground Water. Ground Water Monitoring and Remediation, v. 17, no. 3, p. 177-184. Vroblesky, D.A., and Peters, B.C. 2000. Diffusion Sampler Testing at Naval Air Station North Island, San Diego County, California. November 1999 to January 2000. U.S. Geological Survey Water-Resources Investigations Report 00-4182, 34 p. Vroblesky, D.A., and Petkewich, M.D. 2000. Field Testing of Passive Diffusion Bag Samplers for Volatile Organic Compound Concentrations in Ground Water, Naval Industrial Reserve Ordnance Plant, Fridley, Minnesota. November 1999 and May 2000: U.S. Geological Survey Water-Resources Investigations Report 00-4246, 10 p. Vroblesky, D.A. 2004. Personal Communication to the Project Team during a Teleconference. March 18. APPENDIX A Electronic file provided separately APPENDIX B WELL-SPECIFIC PLOTS DEPICTING VERTICAL Electronic file provided separately APPENDIX C Electronic file provided separately APPENDIX D X-Y SCATTER PLOTS Electronic file provided separately APPENDIX E ELECTRONIC DATA DELIVERABLE Electronic file provided separately APPENDIX F FIELD NOTES Electronic file provided separately APPENDIX G REVIEW COMMENTS AND RESPONSES Electronic file provided separately
Report Cover Table of Contents Sec. 1 Sec. 2 Sec. 3 Sec. 4 Sec. 5 Sec. 6 Sec. 7 Sec. 8
|